UPS IRIS 1000-3000VA

The IRIS UPS series is the ideal solution for home, alarm, healthcare and computer applications.

Smallest footprint with best quality/price ratio !

Eco mode 

More details

Applications

Applications UPS HomeApplication UPS AlarmApplication UPS ComputerVision UPS applications Healthcare

Specifications

  • On-line “double conversion” technology (VFI)
  • Output power factor 0,9
  • DSP (Digital Signal Processor) technology
  • Internal static and manual bypass
  • Intelligent managment through RS232 and USB
  • Site wiring fault indication
  • Battery (DC) cold start
  • Self testing when UPS startup
  • RJ45/11 network protection
  • Input power factor up to 0.99
  • Software and USB cable included
  • EPO contact
  • For extended backup time check IRIS LA series (external batteries)
  • 2 years warranty (electronics)

  • Options: SNMP adapter, relay card (dry contact), external maintenance bypass

LCD display

The comprehensive graphic display provides easy read-out statuts of the UPS from the screen, such as input, voltage, load level, battery level, error code...

Aunilec UPS LCD

1000VA2000VA3000VA
Power (Watt)900W1800W2700W
• Input
Minimum voltage160/115VAC (at 100/50% load)
Maximum voltage290/295VAC (at 100/50% load)
Frequency45-55Hz +/- 0,5Hz or 55Hz-65Hz +/- 0,5Hz (auto-sensing)
Input power factor ≥ 0,99
Bypass voltage range186-252VAC
Harmonic distortion (THD)≤ 7% at 100% non-linear load
• Output
Voltage200/208/220/230/240VAC
Power factor0,9
Harmonic distortion (THD)< 3% at 100% linear load
Frequency50/60Hz +/- 0,2Hz
Voltage stabilization+/- 2%
Crest factor3:1
Efficiency at 75-100% load> 88% (AC mode) / > 90% (battery mode) / > 94% (ECO mode)
• Battery (internal)
TypeVRLA
Voltage24VDC (2x9Ah)48VDC (4x9Ah)72VDC (6x9Ah)
Backup time5-8min with internal batteries / extendable with external batteries
Internal charger power1A
• Protection
RJ11/45 protectionYes
Input / Output protection againstOverload - temperature - short circuit
Overload in battery mode

108% +/-5% < load ≤ 150% +/-5% exceeds 30s cut off & alarm

150% +/-5% < load ≤ 200% +/-5% exceeds 300ms cut off & alarm

Overload in utility mode

108% +/-5% < load ≤ 150% +/-5% exceeds 30s transfer to bypass & alarm

150% +/-5% < load ≤ 200% +/-5% exceeds 300ms transfer to bypass & alarm

• Alarms
Audible alarmBattery backup, battery low, overload status, fault status
LED alarmMains, inverter, bypass, fault, battery level
LCD alarmInput and output voltage, load, battery voltage, error codes
• Bypass
TypeInternal automatic static and manual bypass (external bypass optional)
• Environment
Temperature / Altitude / Humidity0-40°C / less than 1500m / 0-95% non-condensing
Audible noise at 1m< 50dB
• Interface
StandardRS232 / USB (software included) / EPO
OptionalSNMP / Relay card (dry contacts)
• Dimensions
Weight9kg16,4kg25,1kg
WxDxH144x300x215mm144x420x215mm195x480x355mm
• Standard
CertificateCE-Certificate