Specifications

  • 2-step boost and 1-step buck automatic voltage regulator (AVR)
  • Wide input voltage range with simulated sine wave output waveform
  • Multiple output receptacles for convenient usage
  • Tri-directional wall-hanger for convenient storage
  • Advanced green mode for energy saving and user-friendliness settings
  • Automatic self-diagnostic and alarm warning
  • Surge, short circuit, overload and telecommunication protection
  • Discharge and overcharge protection
  • Scheduling shutdown and reboot function
  • Events recorder of power incidents

EPC 650EPC 1000
Capacity650VA1000VA
• Input
Voltage140V to 300V
Frequency50Hz / 60Hz +/-10% auto sensing
• Output
Voltage100/110/115/120V (+/-5% on battery), 220/230/240V (+/-5% on battery)
AVRAVR with 2 steps boost and 1 step buck
Frequency50Hz / 60Hz +/-1Hz
WaveformSimulated sinewave
ConnectionsCustomized receptacle on request
Transfer time6 ms including detection time (typical)
• Protection
OverlaodUPS automatic power off if overload exceeds 110% of nominal at 60sec, 130% at 3sec
Surge800 Joules, 8/20 µS
Short-circuitUPS output cut off immediatly or protected by input circuit breaker
TelecommunicationRJ45x2 (input and output)
FuseYes (circuit breaker)
AlarmBuzzer beeps under backup mode, battery low, battery charging fault, overload
• Battery
TypeSealed, maintenance-free lead acid battery
Typical recharge time8 hours to 90%
Battery quantity12V 7Ah x 112V 9Ah x 1
Backup time for one PC+/- 17minutes+/- 28minutes
ProtectionAutomatic diagnostics, over-discharge and short circuit protection by fuse
• Standard
Dimensions (WxDxH)232x283x103 mm
Weight6,9kg7,8kg
DisplayLED indicator
Communication interfaceUSB B-type
Audible noise< 40dBA (1m from surface)
Ambiant operation0 to 40°C, 0 to 95% humidity (non-condensing)