Rectifier charger RCRFn 24Vcc, 48Vcc, 110Vcc, 220Vcc

These new devices are the result of a research and development  by our company, to have maximum reliability and performance in the field of energy supply systems. 

The electronic controls of the RCRFn rectifiers are reliable and increase the life of batteries.

More details

Applications

Applications industryTelecom rectifier charger

Specifications

Uses:

  • Power for lighting
  • Power for automatism
  • Power for signalisation
  • Power for circuit breakers

Advantages:

  • Input isolation transformer
  • Easy maintenance
  • Advanced technical diagnostic
  • Microprocessor controller
  • High profitability
  • Easy to use

5A to 50A current for the single phase version and 10 to 200A for the three phase version

Wall mounted cabinet for small powers of 24,48 and 110 Vdc with 230vca or 400vca single phase

DC power set

These new devices are the result of a research and development by our company, to have maximum reliability and performance in the field of energy supply systems. We have not chosen to implement only the traditional energy conversion systems (isolating transformer with a thyristor), but liaise flexibility and in advance of a digital logic microcontroller with the latest state-of-the-art technology.

The options available on the RCRFn series:

  • Independent regulation of the load current and battery
  • Charge voltage adjustment depending on the temperature
  • Automatic test (every 15 days)
  • Double load Plan
  • Battery test and insulation monitoring

The electronic controls of the RCRFn rectifiers are reliable and increase the life of batteries.

DC power rectifier charger

Rectifier charger RCRFn
• Electrical data
Input voltage (Vac)230V or 400V single phase or 400V three phase +/-10%
Input frequency50-60Hz +/-5%
Input short circuit current15KA Rms (at Vac nominal, IEC standard)
Input current distortion27 (at nominal power THD%)
Input power factor0,8 (at nominal input voltage 100% load)
Output nominal voltage (Vdc)24-48-110-220
Output current (Amp)50-250 *24VDC and 48VDC
Floating2,27 V/Cell (battery VRLA) / 2,2 + 2,3V/Cell (battery VLA) / 1,4 + 1,5V/Cell (battery Ni-Cd)
Equalization voltage (optional)2,4-2,45/Cell (battery VLA) / 1,5-1,65V/Cell (battery Ni-Cd)
Manual load voltage (optional)2,35V/Cell (battery VRLA) / 2,7V/Cell (battery VLA)/ 1,7V/Cell (battery Ni-Cd)
Output voltage stability1% (at nominal input voltage)
Output ripple1% rms (other on request)
Overload<120% for 20 min, <150% for 1min, >150% for 10 sec (without batteries)
Battery recharging systemIU-DIN41773 - satndard, I1I2U - optional, Manual - optional, thermal compensation - optional
• Environmental data
Accoustic noise level<65 dB with forced ventillation according EN50091
EMIEN61000-6-2, EN61000-6-4
Operating temperature (°C)-10 +40
Storage temperature (°C)-20 +70
Relative humidity (without condensing)< 95%
VentillationForced-natural (depending on power)
Altitude<2000m according EN62040-3
• Mechanical data
Protection degreeIP20 (ref IEC 60529)
ColorRAL 7035-standard
Dimensions (LxPxH), mm600x600x1200, 600x800x1200, 600x800x1900, 800x800x1900
I/O cables connectionFrom below (other on request)
AccessibilityFront